KRQ30 Series AC Motor Soft Starter
01
- ● With CCC certification
- ● Various start modes: torque start, current limit start, pulse jump start
- ● Multiple stop modes: free stop, soft stop
- ● Various starting methods: external terminal start and stop, delayed start
- ● Support motor branch delta connection, which can reduce soft starter capacity
- ● With motor temperature detection function
- ● With programmable analog output interface, real-time monitoring of motor current
- ● Full Chinese display panel, support panel external introduction
- ● Standard RS485 communication interface (Modbus RTU protocol), optional PROFBUS, PROFINET communication gateway
- ● The peripheral port adopts electrical isolation technology, which has strong anti-interference ability and high safety performance
| Power supply | Main circuit power supply: 3AC340~690V, 30~65Hz | |
| Control power supply: AC220V(﹣15%+10%), 50/60Hz; | ||
| Input and output | Control signal: passive switching value
Relay output: contact capacity: 5A / AC250V, 5A / DC30V, resistive load |
|
| Working characteristics | Starting mode: torque starting, current limiting starting and pulse jump starting | |
| Shutdown mode: free shutdown and soft shutdown | ||
| Working mode: short-time working system, starting up to 10 times per hour; After starting, bypass with contactor | ||
| Communication | MODBUS: RS485 interface, standard MODBUS protocol RTU mode, supporting 3, 4, 6 and 16 functions | |
| Protection | System fault: alarm in case of program self-test error | |
| Power fault: protection when the input power supply is abnormal | ||
| Phase inversion prohibition: the operation of reverse phase sequence is prohibited and protection when input is reverse phase sequence | ||
| Overcurrent: current over limit protection | ||
| Overload: I2t overload protection | ||
| Frequent starting: do not start again when the overload is greater than 80% | ||
| Thyristor overheating: protection when the thyristor temperature is greater than the design value | ||
| Thyristor fault: Protection in case of thyristor faiult | ||
| Starting timeout: protection when the actual starting time exceeds twice the set time | ||
| Load unbalance: protection when the unbalance degree of output current exceeds the set parameters | ||
| Frequency fault: protection when the power frequency exceeds the set range | ||
| Ambient |
Service temperature: -10~45℃
Storage temperature: -25~70℃ Humidity: 20%~90%RH, no condensation Altitude: lower than 1000m, more than 1000m according to GB14048 6-2016 national standard derating use Vibration: <0.5G IP grade: IP00 |
|
| Installation | Wall mounted: installed vertically for ventilation | |
| Note: the product continues to innovate and the performance continues to improve. This parameter description is for reference only. | ||